Product Center

Yocon virus sampling products were well accepted globally.

FE4800 Automatic Sample Processing and Nucleic Acid Isolation Workstation

This is an integrated workstation for automatic dispensing, processing and extraction of nucleic acid samples within 20 minutes

Product use

With the normalization of epidemic prevention and control, rounds of large-scale high-intensity nucleic acid testing and screening have exhausted the nucleic acid extraction staff. In this case, it is an inevitable trend to produce an automatic device for replacement of manual work, in order to obtain the nucleic acid test result after a tube is fed. Targeted at large-scale nucleic acid testing, and without complicated extraction steps, YOCON automatic sample processing and nucleic acid extraction workstation can finish automatic dispensing, processing and extraction of viral nucleic acid samples within 20 minutes, greatly reducing manpower.
Product video

Automatic sample processing and nucleic acid extraction workstation

Item

Function

Technical parameters

Sample processing

Form of sample loading and unloading

Put the sampling tube into the push-pull sample rack and push to load or pull to unload the sample.

Number of tubes that can be capped simultaneously

Eight channels are available, enabling 8 sampling tubes capped simultaneously.

Form of sampling tube capping

In-situ capping: leave the top of the sampling tube after in-situ attachment for pipetting; perform in-situ tightening after pipetting to prevent cross-contamination.

Form of sample data recording

The barcode on the sample is scanned by photoelectric scanner, which is completed synchronously with loading.

In-position test of sample rack

It is designed to prevent capping failure due to incomplete insertion in place.

Vortex module positioning

Automatic positioning and locking is carried out after vortex oscillation to prevent sample rack shaking.

Form of virus sample release

In-situ vortex oscillation is carried out with adjustable frequency and time.

Nucleic acid extraction flexibility and speed

Nucleic acid extraction time in quick mode

48 samples/20 min (to be used with YOCON inactivated sampling tube and three-step extraction reagent)

Nucleic acid extraction time in standard mode

48 samples/30 min (to be used with YOCON non-inactivated sampling tube, sampling tubes and extraction reagents of other companies)

Maximum number of samples to be processed in a single cycle

48 servings

Minimum number of samples to be processed in a single cycle

48 servings

Editable extraction steps

Program editing is possible to run one of the steps separately, such as cleaning.

Error-proof design in unattended mode

Anti-capping failure design

A position sensor is available, which senses if the push-pull sample rack is in place to prevent follow-up capping failure.

Anti-pipette collision design

A color sensor is available, which senses if the cap is actually loosened and removed to prevent equipment loss due to collision with the pipette.

Anti-pipette tip installation failure design

A TIP sensor is available, which senses if the pipette tip is installed correctly to prevent no-load running.

Anti-liquid inspiration failure design

An air pressure sensor is available, which senses if it is in contact with liquid to prevent inspiration of air bubbles.

Error prompt

Errors, if any, will be shown on the screen, and the device indicator will flash with beep alarm sounding.

Pipetting

Quantity of simultaneously pipetted samples

8 channels are available, enabling simultaneous transfer of 8 samples.

Pipetting spacing adjustable?

It can be intelligently, dynamically and automatically adjusted with different tube spacings during moving.

Pipetted sample volume range per channel

20uL~1000uL

Pipetting accuracy

20uL,<1.5%100uL,<0.5%

Nucleic acid extraction

Nucleic acid extraction method

By magnetic bead method


Nucleic acid extraction heating module

Available, room temperature - 100 .


Up-suction magnetic rod holder

Up- suction magnetic method enables short extraction time and high efficiency.


Mixed oscillation

Oscillation amplitude and frequency can be adjusted according to the volume of liquid, to ensure the mixing effect and prevent overflow.


Temperature safety module

Both temperature sensor and temperature protection switch are available to ensure the safety of equipment and personnel.


Temperature control range of nucleic acid extraction heating module

± 0.5

Nucleic acid transfer

Nucleic acid transfer mode

Transfer to a 48-well plate, or to a 96-well plate or to an 8-plex PCR tube.

Biosafety assurance

Negative pressure working environment throughout the workstation

Equivalent to B2 level biosafety cabinet

Anti-drip system

The anti-drip module moves underneath the pipette in real time, to prevent contamination of other samples by fallen liquid or detached tips in extreme cases.

Disinfection and sterilization of the operating environment

Efficient UV lamp

Additional safety cabinet installation issues


Heat sealing of waste

Heat sealing of waste

The used pipette tips are threw directly into the medical waste bag for disposal before heat sealing.

Supporting reagents

Virus sampling tube

Multi-optional. YOCON inactivated sampling tubes, YOCON non-inactivated sampling tubes or others are allowed.

Nucleic acid extraction reagent

Multi-optional. YOCON three-step extraction reagent or YOCON five-step extraction reagent or others are allowed.

Supporting consumables

Pipette tips

Standard pipette tips, 1,000 ul and 50 ul.

Deep-well plate

Standard

96-well or 48-well PCR plate

Standard

Equipment control

Technical mode

High performance computer for industrial control

Supporting program

Upper computer software

Control mode

Touch screen

Display

12.1" display

Resolution

1024×768

Interface mode

Data export, connection with LIS system and remote control are supported.

General parameters

Working temperature

10~30

Working humidity

< 80%, non-condensing

Dimensions

1,600 mm (W) × 880 mm (D) × 1,950 mm (H)

Easy equipment transfer design

The equipment is lower than the conventional door frame in height and width, and equipped with load-bearing wheels for easy transfer.

Voltage and power

220V50Hz1600W

Weight

490kg


Product advantages

Tube loading

Virus sampling tubes can be directly loaded without manual pre-dispensing to obtain the nucleic acid test results for the true realization of unattended automation

Sample traceability

The barcode on the sample loaded is automatically scanned, which is completed synchronously with loading. Full traceability and data recording in memory are allowed to ensure that samples are traceable

Automatic oscillation

The in-situ vortex oscillation program is started after loading with adjustable frequency and time to fully release the sample and improve the detection rate. It allows automatic positioning and locking after oscillation to prevent follow-up extraction due to sampling tube displacement

Adjustable pipetting spacing

With multi-optional reagents and consumables, pipetting spacing can be automatically adjusted according to the sampling tube spacing. YOCON’s higher investment guarantees lower use cost of customers

Eight-channel capping

The original automatic capping arm allows simultaneous loosening or tightening of 8 sampling tube caps. The number of channels does not represent the efficiency of sample processing, but the number of samples processed at one time can truly reflect the efficiency

Anti-aerosol contamination

Yocon original air duct against anti-aerosol contamination can effectively prevent “false positive” caused by system contamination

Intelligent early warning

A variety of built-in sensors are available, which will activate the audible and visible alarm programs and notify the corrections in the event of mis-touch in operation, consumables displacement, or inspiration of air bubbles by mistake during reagent inspiration

Automatic dispensing system

Reagents are automatically dispensed to deep-well plates, and nucleic acids are automatically dispensed into 96-well plates at the end of extraction, without manual pipetting throughout the process

Multi-optional reagents and consumables

It is suitable for all octagonal base sampling tubes and magnetic bead nucleic acid extraction reagents available on the market to provide a freer operating experience

Touch screen control

The advanced control system of the mainboard with the screen as an automatic control module, allows extraction process view and touch screen precise control at any time

Data download